WCM 031715Ceiling MountOWNER’S MANUALThe Coolest Thing In Wine Storage
Page 8 | 1-800-343-9463WCM 031715BEFORE YOU START 1. Inspect the system before installation. If damage is found, please contact your distributor or Wh
www.whisperkool.com | Page 9The performance and life of your system is contingent upon the steps you take in preparing the wine cellar. Note: Improper
Page 10 | 1-800-343-9463WCM 031715Unobstructed Air owUnobstructed airflow to and from the system is critical for the system’s overall performance and
www.whisperkool.com | Page 11Ambient Temperature FactorThe cooling system has the ability to cool a wine cellar e ciently to 55°F as long as the amb
Page 12 | 1-800-343-9463WCM 031715Minimum Tools Needed: Fully ExposedMounting OptionFlush MountMounting Option Choose a Mounting Option suitable for t
www.whisperkool.com | Page 13NOTES
Page 14 | 1-800-343-9463WCM 031715INSTALLING THE EVAPORATOR UNIT (TYPICAL INSTALLATION)ITEMS TO ROUTE BEFORE INSTALLING THE EVAPORATOR1. Route the li
www.whisperkool.com | Page 15INSTALLING THE EVAPORATOR UNIT WITH ATTIC ACCESSFigure 1TOP VIEW1. Place the evaporator on a working table with the Top
Page 16 | 1-800-343-9463WCM 031715INSTALLING THE EVAPORATOR UNIT WITH ATTIC ACCESSPREPARING THE EVAPORATOR FOR INSTALLATION CONTINUED12. If you have p
www.whisperkool.com | Page 17Single Piece Mounting BracketThe mounting bracket has been designed to secure the unit to the ceiling. Install the mounti
WCM 031715Copyright © 2012. WhisperKOOL. All rights reserved. WhisperKOOL copyrights this manual, the product design, and the design concepts, with al
Page 18 | 1-800-343-9463WCM 0317151. Insert the following items into the unit through the removed knockouts: power cable wiring, keypad cable, bottle
www.whisperkool.com | Page 19INSTALLING THE EVAPORATOR UNIT WITH ATTIC ACCESSCONNECTING THE EVAPORATOR UNIT IN THE ATTIC12. If you have purchased the
Page 20 | 1-800-343-9463WCM 031715220V CONNECTION FOR CEILING MOUNT EVAPORATOR UNIT1. Connect the supplied power cord with the exposed wire ends to t
www.whisperkool.com | Page 21INSTALLING THE UNIT FROM INSIDE THE CELLARNOTE: The Ceiling Mount Unit can still be used even with limited or no above ce
Page 22 | 1-800-343-9463WCM 031715INSTALLING THE UNIT FROM INSIDE THE CELLAR6. Remove the eight screws securing the supply/return air grille.7. Gras
www.whisperkool.com | Page 23INSTALLING THE UNIT FROM INSIDE THE CELLAR12. Connect the line set to the liquid and suction lines on the evaporator. No
Page 24 | 1-800-343-9463WCM 031715Drain LineThe Ceiling Mount evaporator features a drain line pump system that removes excessive condensate build up
www.whisperkool.com | Page 25LIQUID TEMPERATURE - MEASURING THERMOSTATThe WhisperKOOL Series cooling units come equipped with a liquid temperature mea
Page 26 | 1-800-343-9463WCM 031715Note: A 50ft communication cable is included and the keypad can be installed up to 300 feet away from the evaporator
www.whisperkool.com | Page 27ACTIVE HUMIDITY OPTION OVERVIEWUse of the Active Humidity OptionHumidity may uctuate in the wine cellar. The Active Hum
www.whisperkool.com | Page 1TABLE OF CONTENTSQuick Reference GuideUnit ...Knockout Location ...
Page 28 | 1-800-343-9463WCM 031715HUMIDISTAT INSTALLATIONFigure 3Humidistat InstallationOnly a 120-Volt humidistat can be used with this unit. Routing
www.whisperkool.com | Page 29HUMIDISTAT INSTALLATIONMounting With a Wall Mount Plate1. Make sure the humidistat is unplugged before installingthe unit
Page 30 | 1-800-343-9463WCM 031715CEILING MOUNT WIRING DIAGRAM1 41 4BlackGreenWhiteBlackWhiteBrownBlackBlueWhite(1)(4)Ref.SolenoidUse CopperConductor
www.whisperkool.com | Page 31CEILING MOUNT WITH HUMIDITY WIRING DIAGRAM1 41 4COMPNC C NO34 278 61BlackRedBlackGreenWhiteBlack1 41 4BlueBlackWhiteWhite
Page 32 | 1-800-343-9463WCM 031715CEILING MOUNT 4000 CONDENSING UNIT WIRING DIAGRAMPage 25Platinum Split 4000 & 8000 Condenser Terminal Board
www.whisperkool.com | Page 33CEILING MOUNT 8000 CONDENSING UNIT WIRING DIAGRAMLEGEND:TERMINAL BOARDBD # SERVES COLOR1 GROUND GREENUK GREEN/YELLOW STRI
Page 34 | 1-800-343-9463WCM 031715INSTALLING THE CONDENSING UNITCC HEATERCOMPRESSORLPHP TDCCCOND. FANPOWER115v 60 HZHNLOW AMBIENTCONTROLCC COMP CONTAC
www.whisperkool.com | Page 35Electrical Needs The condensing unit requires a dedicated 115 volt 20 amp circuit. The unit draws a large inrush current
Page 36 | 1-800-343-9463WCM 031715CONDENSING UNIT QUICK REFERENCE GUIDESuction Line Secure ValveCeiling Mount 8000 Condensing Unit Ceiling Mount 4000
www.whisperkool.com | Page 37PREPARING THE CONDENSING UNIT (continued)Installing the Condensing Unit The condensing unit can be installed inside a wel
Page 2 | 1-800-343-9463WCM 031715QUICK REFERENCE GUIDE Top View Bottom ViewMounting Bracket (Paintable)Supply and Return Grille (Paintable)Evaporator
Page 38 | 1-800-343-9463WCM 031715Wiring Procedures Ceiling Mount 40001. Locate or install an electrical outlet near the condensing unit.2. Plug the
www.whisperkool.com | Page 39Wiring Procedures Ceiling Mount 80001. Route 14 AWG copper wiring to the condensing unit.2. Remove screw securing the c
Page 40 | 1-800-343-9463WCM 031715LINE SET PIPING DIAGRAMSThese are two options for running the line set from the coil to the condensing unit. Option
www.whisperkool.com | Page 41Refrigerant Piping Overview• Using the charts and illustrations found on previous pages, route the line set between the
Page 42 | 1-800-343-9463WCM 031715INSTALLING THE CONDENSING UNITFINALIZING THE INSTALLATIONEvacuation• Remove the nitrogen tank from the manifold and
www.whisperkool.com | Page 43SYSTEM OPERATIONInitial Start-UpWhen power is applied to the unit, the control will briey display all symbols, and the S
Page 44 | 1-800-343-9463WCM 031715CONTROLLER FUNCTIONSButton Normal FunctionsON/OFF • The ON/OFF button allows the customer the convenience of turnin
www.whisperkool.com | Page 45Set 1. Press the “Set” button once and it will display the set point. After approximately 5 seconds, the display will ret
Page 46 | 1-800-343-9463WCM 031715CPSM Mode Press the “Set” and the “DOWN” buttons simultaneously, for 3-5 seconds and you will access the “Customer P
www.whisperkool.com | Page 47MAINTENANCE SCHEDULEMonthly 1. Check for debris surrounding condensing unit(i.e. leaves, branches, trash ect.). Remove al
www.whisperkool.com | Page 32 x1.50 Knockout(Both Sides)2 x0.84 THRU2 x1.50 Knockout2 x 0.84 THRUDCBAABCD1234567887654321PROPRIETARY AND CONFIDENTIALN
Page 48 | 1-800-343-9463WCM 031715TROUBLESHOOTING GUIDEUnit has ice forming on the evaporator Possible Cause Evaporator lter or coil is dirty. T
www.whisperkool.com | Page 49TROUBLESHOOTING GUIDESolutionEvaporator unit should be level in wall to prevent leaking.Check drain line to make sure wat
Page 50 | 1-800-343-9463WCM 031715TECHNICAL ASSISTANCEWhisperKOOL Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Paci
www.whisperkool.com | Page 51WhisperKOOL Product Terms and Conditions Including Product Limited Warranty And Product Installation Requirements For Wh
Page 52 | 1-800-343-9463WCM 031715• Incorrect tubing diameter used on line set• A unit that has been wired incorrectly• Valve stem on condenser sid
www.whisperkool.com | Page 533. Maintenance RequirementsThe End User is responsible for checking the coils on the condenser unit and vacuuming them ev
Page 54 | 1-800-343-9463WCM 0317157. Request for Product Evaluation and Repair Under Warranty SPLIT SYSTEM FIELD SERVICE WARRANTY POLICY: This Policy
www.whisperkool.com | Page 55Model ______________________________________ Serial Number __________________________Installed by _____________________
WCM 031715 WhisperKOOL1738 E. Alpine AveStockton, CA 952051-800-343-9463www.whisperkool.com
Page 4 | 1-800-343-9463WCM 031715QUICK REFERENCE GUIDEController LayoutRefer to page 44 for complete listing of buttons and symbols.°FCompressor is On
www.whisperkool.com | Page 5CEILING MOUNT SPECIFICATIONSModel8000 Evaporator(Fan Coil Unit)8000 Condenser(Air Cooled Condensing Unit)Cellar Size (cu.
Page 6 | 1-800-343-9463WCM 031715WARRANTY REGISTRATIONIn order to activate the warranty of your system, the Verication and Operational Documentation
www.whisperkool.com | Page 7Receiving and Inspecting the System • Lift only at the designated hand hold locations on the shipping container or fully